Emergency Shut-Off Valve
|
|
 Emergency Shut-Off Valve
The 800X pressure difference balance valve is a kind of valve intended for use between the water supply part and the return water part of an air conditioning system to balance the pressure difference. The 900X emergency shut-off valve belongs to a kind of valve that is intended for use in a water supply system in which the fire fighting water and domestic water are connected in parallel and for the control of the direction of water supply. When a fire breaks out and a large quantity of water is in great need for fire fighting purpose, the 900X emergency shut-off valve cuts off the domestic water supply immediately so as to ensure enough fire fighting water. When the fire fighting is over and the pressure in terms of water use has dropped, the valve switches on automatically to stay in the constantly open state and the normal domestic water supply is restored. This valve makes it unnecessary to set a separate fire fighting water supply network in the system, thereby greatly reducing the construction cost and water consumption. Furthermore, the valve is high in control sensitivity, safe, reliable, simple to debug and offers a long service life. Pressure Rating: PN10. PN16. PN25/Class150Size Range: DN20mm-DN800mm (3/4" - 32")Test and inspection: GB/T 13927 API598
Main Technical Features:
|
PN |
1.0MPa |
1.6MPa |
2.5MPa |
|
Shell Test |
1.5MPa |
2.4MPa |
3.75MPa |
|
Seal Test |
1.1MPa |
1.76MPa |
2.75MPa |
|
Suitable Temperature |
?0? |
|
Suitable Medium |
Water | Dimensions( mm):
|
DN |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
400 |
450 |
|
L |
150 |
160 |
180 |
200 |
203 |
216 |
241 |
292 |
330 |
356 |
495 |
622 |
698 |
787 |
914 |
978 |
|
H1 |
247 |
247 |
247 |
278 |
278 |
298 |
313 |
350 |
365 |
420 |
450 |
470 |
490 |
526 |
570 |
570 |
|
H |
342 |
342 |
342 |
395 |
395 |
405 |
430 |
510 |
560 |
585 |
675 |
730 |
760 |
840 |
910 |
910 |
|
|
|
|
|
|
|
|
100X Remote Control Float Ball Valve
|
| The main valve is controlled by a float ball valve which locates on the top of tank or reservoir. The valve maintains the maximum water level of tank or reservoir continuously. |
|
|
|
|
|
|
|
| | | |
|
|
|
|
|
|
300X Flow Control Check Valve
|
The valve is used at outlet pipe of pump, with its open & close speed adjustable, and also used at high building for reducing water hammer & water slamming.
|
|
|
|
|
|
|
|
| | | |
|
|
|
|
|
|
600X Electrical Control Valve
|
| The valve is controlled by solenoid valve and can implement remote open & close operation to substitute electrical driven gate valve or butterfly vale. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
700X Pump Control Valve
|
| The valve eliminates damaging water surges (hammer) caused when pump starts up and shuts off. The electrically activated valve gradually opens when pump starts up, and slowly closes before the pump is switched off. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
800X Pressure Difference Balance Valve
|
The 800X pressure difference balance valve is a kind of valve intended for use between the water supply part and the return water part of an air conditioning system to balance the pressure difference.
|
|
|
|
|
|
|
|
| |
|
|
|